Overview
The Static Var Generator (SVG) is a leading solution for reactive energy compensation, designed to meet the demands of modern networks facing challenges like increased harmonics and voltage fluctuations from renewable energy sources. Its DSP-controlled IGBT topology ensures effective phase compensation for both inductive and capacitive loads, while also correcting phase imbalances. With resistance to harmonics and resonance, the SVG offers a maintenance-free solution that can easily integrate into any network configuration, making it suitable for today’s evolving energy landscape.
Applicable occasion
1.Hoists, rolling mills, and other heavy industry applications are typical impact loads, primarily found in mining and metallurgical industries. They have the following impacts on the power grid:
The reactive power impact is large, resulting in power grid voltage fluctuations, serious interference with the operation of other equipment, reducing production efficiency;
Low power factor, monthly need to pay a large amount of reactive power fines;
Some devices produce harmonics, endangering the safety of power grid.
2. The main loads of the oil and gas drilling platform power supply system include winches, turntables, mud pumps, etc. Due to the specific conditions of drilling, the system represents a typical impact load. The impacts on the power grid are as follows:
Large reactive power impact, low power factor;
High current harmonics;
The voltage fluctuation is serious and the voltage distortion rate is high, which affects the power supply of the control system, PLC, logging instrument and other equipment.
Product Features
Dynamic Reactive Power Compensation
Continuously monitors and adjusts reactive power output to maintain stability and efficiency during load variations, with an adjustable power factor ranging from -1 to +1.
High-Efficiency Control
Incorporates Insulated Gate Bipolar Transistor (IGBT) technology for effective power conversion, significantly minimizing energy losses and boosting overall system efficiency.
Power Factor Improvement
Effectively raises the power factor close to unity (1.00), resulting in reduced electricity costs and decreased strain on the grid, ultimately benefiting businesses economically.
Harmonic Suppression
Features integrated harmonic filtering capabilities that suppress harmonic distortion within the grid, safeguarding electrical equipment and extending its lifespan.
Modular Design
The modular design allows for easy expansion and maintenance, providing flexibility to adapt to various power system scales and requirements, while supporting future upgrades.
User-Friendly Interface
Equipped with an intuitive Human-Machine Interface (HMI) that enables operators to monitor and adjust system parameters in real-time, improving operational efficiency.
Reliability and Stability
Undergoes extensive testing to ensure dependable performance under diverse operating conditions, capable of withstanding challenging environments to ensure safe operation.
Multi-Functional Integration
Offers a range of functions, including reactive power compensation, load balancing, and harmonic filtering, delivering a comprehensive solution for diverse user needs.
Input | Rated voltage | 380V (allowable fluctuation range-40% ~ +20%) |
Rated frequency | 50 ± 2Hz | |
Compensation capacity | 50 kvar, 75 kvar, 100 kvar, 200 kvar, Parallel expandable capacity | |
Performance indicators | Overall machine efficiency | ≥ 97%, excess capacity is compensated according to maximum capacity |
CT Requirements | Three CTs, accuracy level 0.5 or above, secondary current 5A | |
Range of compensation | Inductive reactive power and capacitive reactive power can be continuously replenished | |
Switching frequency | Average 20KHz | |
Neutral filtering capability | 3 times phase line current | |
Response time | 40uS | |
Full response time | 10mS | |
Self-diagnostic function | Fault self-diagnosis, automatic switching, automatic restart | |
Compensatory capacity | Full compensation when it is within the equipment capacity, and the time limit exceeding the equipment capacity is defined as the rated compensation capacity | |
Protection function | Overcurrent, power grid overvoltage, undervoltage, overheating, bus overvoltage,undervoltage, short circuit, fan failure, power failure and current limiting protection, etc. | |
Display data and records | 1. Voltage and current, power factor, THD and other parameters of each phase; | |
Communication interface | Rs485, Ethernet | |
Communication protocol | Modbus discussion | |
Environmental Conditions | Man-machine interface | 5-inch or 10-inch touch screen |
Ambient temperature | -10C ~ +45C | |
Elevation | < 2 km, higher altitude can be derated | |
Level of protection | IP20 | |
Structure | Cooling method | Intelligent air cooling |
Installation method | Wall-mounted, drawer-mounted, whole cabinet drawer-mounted | |
Dimensions | See "Selection Dimensions" for details |
Home Products Industry Solution Application Customization About News Contact Us
Copyright © Zhejiang Zhegui Electric Co., Ltd. is founded in Zhejiang, China. SItemap