PRODUCTS
Home / Products / Circuit Breaker / Vacuum circuit breaker / Three phase pole mounted 24kV Power distribution Vacuum Circuit breaker

Three phase pole mounted 24kV Power distribution Vacuum Circuit breaker

Place of Origin:Zhejiang,
Brand Name:Zhegui Electric
Model Number:ZW32
Type:Vacuum
Breaking Current:20kA
Mechanical Life: 10000 Times
Certificate:ISO CCC IEC
Rated Voltage:
Rated Current:
Rated Frequency:
Availability:
facebook sharing button
twitter sharing button
line sharing button
linkedin sharing button
whatsapp sharing button
sharethis sharing button
  • ZW32

  • Giantele

  • 12/24/33/40.5kV

  • 630A/1250A/1600A/2000A/2500A

  • 50/60HZ

  • 1 piece

1

Overview

      ZW32-12 outdoor high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is outdoor distribution equipment with rated voltage of 12kV and three-phase AC of 50Hz. It is mainly used to open and close load current, overload current and short circuit current in power system. It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume,  lightweight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and a dirty environments.WHY CHOOSE US

O1CN01i2IluX2LTu8G5JZsK_!!3269959694-0-cib (1)

Working Conditons

1. The environment temperature: upper limit +40C. lower linit-30℃

2. Altitude s 2000 meters

3. Wind pressure: no more than 700Pa (corresponding to the wind speed 34m/s)       

4. Earthquake intensity: do not exceed 8 degree

5. Pollution grade: I class

6. Maximum daily temperature: less than 25℃.

Types of meaning

Z W 32 - 12   (  ) / (  ) - (  )
Vacuum
circuit
breaker
Conditions
of use:
outdoor
Design
code
Rated
voltage
(kV)
G-installation
of outdoor
isolating
switch
Rated
current
(A)
Rated short
circuit
breaking
current (kA)


Vacuum Tuoe Details

    The large vacuum tube used in the zhegui circuit breaker is twice as large asthe ordinary vacuumtube, the outer insulation is corrosion-resistant andwear-resistant, and has the characteristics of large breaking capacity, longcontact life and many allowable breaking times

c35aef390415b094a2660692afea12e

Product Description

a27c595772a01261648e3ebbf49b5f6

    Each vacuum tube will have a factory number. After thevacuum tube is produced and stored for 8-12 months, it willbe tested whether there is air leakage and whether thepressure resistance passes the market. Most manufacturerssell it now and will not carry out secondary testing


     The vacuum tube used in zhegui vacuum circuit breakerhas been tested for the second time, and the third time willbe tested after installing the vacuum circuit breaker, so youcan buy it at ease

Vacuum Tuoe Details

    All transformers of this product are made of pure red copper, while ordinaryones are made of copper-clad aluminum. Direct use of copper-cladaluminum is easy to cause great potential safety hazards

c682087ae313b95ae3543989fe10861

Copper isolating knife

    The components used in the vacuum circuit breaker are made of real materials. The thickness of the isolation knife is as high as 2.8mm.The ordinary isolation knife is only 2.0mm. Even various operating handles are made of high-quality materials

10

Copper inler and onule tcontacts

Real material                              Not afraid of test 

The interior is full red copper and the outer layer is tinned

11

Outgoing contact of circuit breaker                     Incoming contact of circuit breaker  

Inerlligent control operation mechanism

True dare to show the agency navigation strictly choose new genuine refused to renovate

12



PRODUCT SIZE DESCRIPTION

4

PRODUCT STRUCTURE DESCRIPTION


5

                                                                1. Upper outgoing terminal                                        11. Operating handle

                                                                2. Circuit breaker                                                          12. Isolation frame

                                                                3. Lifting ring                                                                  13. Insulator

                                                                4. Nameplate                                                                 14. Lower incoming terminal

                                                                5. Opening and closing signboard                             15. Isolation blade

                                                                6. Energy storage operating handle                          16. Insulated pull rod

                                                                7. Energy storage signboard                                       17. Current transformer

                                                                8. Opening and closing operating handl                   18. Voltage transformer

                                                                9. Interlocking shaft                                                      19. Controller

                                                                10. Box                                                                             20. Aviation plug-in

 



    

                 










Main technical parameters

ItemUnitParameter
Voltage, current parameters

Rated voltagekV12
Rated short time power frequency withstand voltage (1min)kV42
Rated lightning impulse withstand voltage (peak)kV75
Rated frequencyHz50/60
Rated currentA6301250
Rated short-circuit breaking currentkA20
Rated short-time withstand current (RMS)kA20
Rated peak withstand currentkA50
Rated short-circuit closing currentkA50
Rated single/back-to-back capacitor bank breaking currentA630/400
Rated short-circuit current durationS4
Rated short-circuit current breaking timestimes50
The main circuit resista neeμΩ≤80(140)
Rated operational voltage
≌220
Mechanical lifetimes10000
The overcurrent regulating Al~10
Quick-break current A6~20
The delay time ms40-850
Remote control distanee m>30
Reclose time times0~3
Rated operating sequenee 
O-0.3s-CO-180s-CO
CTRatioA0/5
CapacityVA15
The output voltageAAC220
The output capacityW600
The overcurrent regulatingAl~10
The delay timems40-850
Remote control distance m30




Previous: 
Next: 
We will work with other excellent partners to deliver more high-quality products to the world.

QUICK LINK

PRODUCT CATALOG

MAKE AN ENQUIRY

Copyright © Zhejiang Zhegui Electric Co., Ltd. is founded in Zhejiang, China.   SItemap