The SCB(10) dry-type transformer embodies the cutting edge of electrical power conversion technologies, effectively combining epoxy resin casting techniques with high-quality insulation materials. This advanced design ensures unmatched efficiency, reliability, and safety, making it ideal for a variety of applications. From distribution networks to commercial and industrial facilities, the SCB(10) transformer is particularly well-suited for environments where strict environmental and fire safety standards are essential. Its dry-type construction eliminates the risk of oil leaks, enhancing safety while reducing maintenance needs. As a result, the SCB(10) transformer is a perfect choice for industries seeking a robust and efficient solution for their power distribution needs.
Rated Voltage: | |
---|---|
Rated Frequency: | |
Rated Capacitor: | |
Availability: | |
SC(B)10
Giantele
10kV、20kV、35kV
50-2500kVA
50/60HZ
Three
1 piece
The SCB(10) dry-type transformer stands as a testament to the latest advancements in electrical power conversion technologies. Engineered with state-of-the-art epoxy resin casting techniques and superior insulation materials, this transformer offers unmatched efficiency, reliability, and safety. Designed to accommodate a broad spectrum of applications—from distribution networks to commercial and industrial facilities—the SCB(10) excels particularly in environments that demand strict adherence to environmental and fire safety standards. With a three-phase configuration and a frequency of 50Hz, this MV dry type transformer operates seamlessly under various load demands, making it a versatile choice for any industrial setting.
One of the standout features of the SCB(10) is its remarkable efficiency and energy savings. Utilizing top-tier magnetic core materials and an innovative winding configuration, this power dry type transformer dramatically reduces both no-load and load losses, significantly boosting overall energy efficiency. This makes the SCB(10) not only a cost-effective choice but also an environmentally responsible one. The commitment to environmental stewardship is further underscored by the elimination of liquid insulation mediums, thus sidestepping potential leakage and pollution issues.
Safety is paramount in any industrial application, and the SCB(10) does not compromise in this area. It leverages flame-retardant materials combined with a sophisticated temperature control mechanism to ensure unwavering performance even in the most strenuous conditions. Additionally, meticulous design and manufacturing practices ensure that the transformer operates at whisper-quiet levels, enhancing the comfort of the workplace environment.
Durability and low maintenance are hallmarks of the SCB(10) dry type transformer. Its streamlined design, combined with premium materials and craftsmanship, promises an extended service life with minimal upkeep. Designed for both indoor and outdoor installations, this MV power dry type transformer adapts easily to various settings and load demands, making it an ideal choice for diverse applications.
The advanced epoxy resin casting technique guarantees the uniform distribution of insulation material across windings, enhancing insulation integrity and longevity. The use of H-class epoxy resin not only provides superior insulation but also withstands higher operational temperatures, reinforcing the transformer's durability and safety. Moreover, the construction employs copper strip windings, which enhance mechanical robustness and thermal dissipation, enabling the transformer to endure sudden short-circuiting without damage. An efficient heat management system further ensures optimal internal conditions by proficiently handling and expelling operational heat, contributing to the SCB(10)’s reliability and efficiency.
In summary, the SCB(10) dry type transformer is engineered to meet the rigorous demands of modern industrial facilities, making it a smart investment for businesses aiming to enhance their power management capabilities while adhering to safety and environmental standards. Whether you're in need of a 33kV dry type transformer or a 300kVA dry type transformer, the SCB(10) is designed to exceed expectations in performance and reliability.
The SCB(10) dry-type transformer stands as a testament to the latest advancements in electrical power conversion technologies. Engineered with state-of-the-art epoxy resin casting techniques and superior insulation materials, this transformer offers unmatched efficiency, reliability, and safety. Designed to accommodate a broad spectrum of applications—from distribution networks to commercial and industrial facilities—the SCB(10) excels particularly in environments that demand strict adherence to environmental and fire safety standards. With a three-phase configuration and a frequency of 50Hz, this MV dry type transformer operates seamlessly under various load demands, making it a versatile choice for any industrial setting.
One of the standout features of the SCB(10) is its remarkable efficiency and energy savings. Utilizing top-tier magnetic core materials and an innovative winding configuration, this power dry type transformer dramatically reduces both no-load and load losses, significantly boosting overall energy efficiency. This makes the SCB(10) not only a cost-effective choice but also an environmentally responsible one. The commitment to environmental stewardship is further underscored by the elimination of liquid insulation mediums, thus sidestepping potential leakage and pollution issues.
Safety is paramount in any industrial application, and the SCB(10) does not compromise in this area. It leverages flame-retardant materials combined with a sophisticated temperature control mechanism to ensure unwavering performance even in the most strenuous conditions. Additionally, meticulous design and manufacturing practices ensure that the transformer operates at whisper-quiet levels, enhancing the comfort of the workplace environment.
Durability and low maintenance are hallmarks of the SCB(10) dry type transformer. Its streamlined design, combined with premium materials and craftsmanship, promises an extended service life with minimal upkeep. Designed for both indoor and outdoor installations, this MV power dry type transformer adapts easily to various settings and load demands, making it an ideal choice for diverse applications.
The advanced epoxy resin casting technique guarantees the uniform distribution of insulation material across windings, enhancing insulation integrity and longevity. The use of H-class epoxy resin not only provides superior insulation but also withstands higher operational temperatures, reinforcing the transformer's durability and safety. Moreover, the construction employs copper strip windings, which enhance mechanical robustness and thermal dissipation, enabling the transformer to endure sudden short-circuiting without damage. An efficient heat management system further ensures optimal internal conditions by proficiently handling and expelling operational heat, contributing to the SCB(10)’s reliability and efficiency.
In summary, the SCB(10) dry type transformer is engineered to meet the rigorous demands of modern industrial facilities, making it a smart investment for businesses aiming to enhance their power management capabilities while adhering to safety and environmental standards. Whether you're in need of a 33kV dry type transformer or a 300kVA dry type transformer, the SCB(10) is designed to exceed expectations in performance and reliability.
Voltage level (kv) | Maximum operating voltage kV(effective value) | Rated short-time power frequency withstand voltage kV(RMS)/1 minute | Rated lightning impulse withstand voltage kV (peak) | |
Full wave | Clipped wave | |||
0.4 | 0.46 | 5 | 75 | 85 |
10 | 12 | 35 | 75 | |
20 | 24 | 50 | 125 | |
35 | 42 | 70 | 170 |
Model meaning(10KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-30 | 30 | Yyn0 or Dyn11 | 10 6.3 6 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 190 | 700 | 2.4 | 4.0 |
SCB10-50 | 50 | 270 | 990 | 2.4 | |||||
SCB10-80 | 80 | 360 | 1370 | 1.8 | |||||
SCB10-100 | 100 | 400 | 1570 | 1.8 | |||||
SCB10-125 | 125 | 470 | 1840 | 1.6 | |||||
SCB10-160 | 160 | 540 | 2120 | 1.6 | |||||
SCB10-200 | 200 | 620 | 2520 | 1.4 | |||||
SCB10-250 | 250 | 720 | 2750 | 1.4 | |||||
SCB10-315 | 315 | 880 | 3460 | 1.2 | |||||
SCB10-400 | 400 | 970 | 3980 | 1.2 | |||||
SCB10-500 | 500 | 1160 | 4870 | 1.2 | |||||
SCB10-630 | 630 | 1300 | 5950 | 1.0 | 6.0 | ||||
SCB10-800 | 800 | 1520 | 6950 | 1.0 | |||||
SCB10-1000 | 1000 | 1770 | 8120 | 1.0 | |||||
SCB10-1250 | 1250 | 2090 | 9690 | 1.0 | |||||
SCB10-1600 | 1600 | 2450 | 11730 | 1.0 | |||||
SCB10-2000 | 2000 | 3050 | 14450 | 0.8 | |||||
SCB10-2500 | 2500 | 3600 | 17170 | 0.8 |
Model meaning(20KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-50 | 50 | Yyn0 or Dyn11 | 20 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 345 | 1180 | 2.4 | 6.0 |
SCB10-100 | 100 | 545 | 1910 | 2.2 | |||||
SCB10-160 | 160 | 682 | 2780 | 1.8 | |||||
SCB10-200 | 200 | 745 | 2820 | 1.8 | |||||
SCB10-250 | 250 | 855 | 3280 | 1.6 | |||||
SCB10-315 | 315 | 980 | 3910 | 1.6 | |||||
SCB10-400 | 400 | 1165 | 4640 | 1.4 | |||||
SCB10-500 | 500 | 1365 | 5550 | 1.4 | |||||
SCB10-630 | 630 | 1545 | 6550 | 1.2 | |||||
SCB10-800 | 800 | 1775 | 7910 | 1.2 | |||||
SCB10-1000 | 1000 | 2090 | 9370 | 1.0 | |||||
SCB10-1250 | 1250 | 2410 | 11050 | 1.0 | |||||
SCB10-1600 | 1600 | 2820 | 13300 | 1.0 | |||||
SCB10-2000 | 2000 | 3280 | 15690 | 0.8 | |||||
SCB10-2500 | 2500 | 3910 | 18550 | 0.8 |
Model meaning(35KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-50 | 50 | Yyn0 or Dyn11 | 35 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 500 | 1360 | 2.8 | 6.0 |
SCB10-100 | 100 | 640 | 2000 | 2.4 | |||||
SCB10-160 | 160 | 800 | 2690 | 1.8 | |||||
SCB10-200 | 200 | 890 | 3180 | 1.8 | |||||
SCB10-250 | 250 | 1000 | 3640 | 1.6 | |||||
SCB10-315 | 315 | 1190 | 4320 | 1.6 | |||||
SCB10-400 | 400 | 1390 | 5180 | 1.4 | |||||
SCB10-500 | 500 | 1640 | 6360 | 1.4 | |||||
SCB10-630 | 630 | 1880 | 7360 | 1.2 | |||||
SCB10-800 | 800 | 2180 | 8640 | 1.2 | |||||
SCB10-1000 | 1000 | 2460 | 10000 | 0.9 | |||||
SCB10-1250 | 1250 | 2860 | 11910 | 0.9 | |||||
SCB10-1600 | 1600 | 3180 | 14820 | 0.9 | |||||
SCB10-2000 | 2000 | 3860 | 17460 | 0.9 | |||||
SCB10-2500 | 2500 | 4500 | 20900 | 0.9 |
Voltage level (kv) | Maximum operating voltage kV(effective value) | Rated short-time power frequency withstand voltage kV(RMS)/1 minute | Rated lightning impulse withstand voltage kV (peak) | |
Full wave | Clipped wave | |||
0.4 | 0.46 | 5 | 75 | 85 |
10 | 12 | 35 | 75 | |
20 | 24 | 50 | 125 | |
35 | 42 | 70 | 170 |
Model meaning(10KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-30 | 30 | Yyn0 or Dyn11 | 10 6.3 6 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 190 | 700 | 2.4 | 4.0 |
SCB10-50 | 50 | 270 | 990 | 2.4 | |||||
SCB10-80 | 80 | 360 | 1370 | 1.8 | |||||
SCB10-100 | 100 | 400 | 1570 | 1.8 | |||||
SCB10-125 | 125 | 470 | 1840 | 1.6 | |||||
SCB10-160 | 160 | 540 | 2120 | 1.6 | |||||
SCB10-200 | 200 | 620 | 2520 | 1.4 | |||||
SCB10-250 | 250 | 720 | 2750 | 1.4 | |||||
SCB10-315 | 315 | 880 | 3460 | 1.2 | |||||
SCB10-400 | 400 | 970 | 3980 | 1.2 | |||||
SCB10-500 | 500 | 1160 | 4870 | 1.2 | |||||
SCB10-630 | 630 | 1300 | 5950 | 1.0 | 6.0 | ||||
SCB10-800 | 800 | 1520 | 6950 | 1.0 | |||||
SCB10-1000 | 1000 | 1770 | 8120 | 1.0 | |||||
SCB10-1250 | 1250 | 2090 | 9690 | 1.0 | |||||
SCB10-1600 | 1600 | 2450 | 11730 | 1.0 | |||||
SCB10-2000 | 2000 | 3050 | 14450 | 0.8 | |||||
SCB10-2500 | 2500 | 3600 | 17170 | 0.8 |
Model meaning(20KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-50 | 50 | Yyn0 or Dyn11 | 20 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 345 | 1180 | 2.4 | 6.0 |
SCB10-100 | 100 | 545 | 1910 | 2.2 | |||||
SCB10-160 | 160 | 682 | 2780 | 1.8 | |||||
SCB10-200 | 200 | 745 | 2820 | 1.8 | |||||
SCB10-250 | 250 | 855 | 3280 | 1.6 | |||||
SCB10-315 | 315 | 980 | 3910 | 1.6 | |||||
SCB10-400 | 400 | 1165 | 4640 | 1.4 | |||||
SCB10-500 | 500 | 1365 | 5550 | 1.4 | |||||
SCB10-630 | 630 | 1545 | 6550 | 1.2 | |||||
SCB10-800 | 800 | 1775 | 7910 | 1.2 | |||||
SCB10-1000 | 1000 | 2090 | 9370 | 1.0 | |||||
SCB10-1250 | 1250 | 2410 | 11050 | 1.0 | |||||
SCB10-1600 | 1600 | 2820 | 13300 | 1.0 | |||||
SCB10-2000 | 2000 | 3280 | 15690 | 0.8 | |||||
SCB10-2500 | 2500 | 3910 | 18550 | 0.8 |
Model meaning(35KV)
Model number | Rated capacity | Join group label | Voltage combination (kV) | No-load loss | Load loss | No-load current | Short-circuit resistance | ||
kVA | High tension | Tapping range | Low pressure | W | W | % | % | ||
SCB10-50 | 50 | Yyn0 or Dyn11 | 35 | ±2×2.5% or +3×2.5% -1×2.5% | 0.4 | 500 | 1360 | 2.8 | 6.0 |
SCB10-100 | 100 | 640 | 2000 | 2.4 | |||||
SCB10-160 | 160 | 800 | 2690 | 1.8 | |||||
SCB10-200 | 200 | 890 | 3180 | 1.8 | |||||
SCB10-250 | 250 | 1000 | 3640 | 1.6 | |||||
SCB10-315 | 315 | 1190 | 4320 | 1.6 | |||||
SCB10-400 | 400 | 1390 | 5180 | 1.4 | |||||
SCB10-500 | 500 | 1640 | 6360 | 1.4 | |||||
SCB10-630 | 630 | 1880 | 7360 | 1.2 | |||||
SCB10-800 | 800 | 2180 | 8640 | 1.2 | |||||
SCB10-1000 | 1000 | 2460 | 10000 | 0.9 | |||||
SCB10-1250 | 1250 | 2860 | 11910 | 0.9 | |||||
SCB10-1600 | 1600 | 3180 | 14820 | 0.9 | |||||
SCB10-2000 | 2000 | 3860 | 17460 | 0.9 | |||||
SCB10-2500 | 2500 | 4500 | 20900 | 0.9 |